1. General
Installation and service by qualified personnel only
1.1 Applications
Pumps for clear liquids in residential, agricultural, industrial, and other
applications.
- Drawing of water from a well, spring, river, pond, etc. Water should
not be drawn from abyssinian wells (tube, driven well).
1.2 Technical description
1.2.1 Performance and electrical data (Table 1)
Permissible temperature range
Maximum ambient temperature
Maximum permissible working pressure
Mains voltages:
Speed (RPM)
Mains fuse protection
Protective system
Insulation class
Sound pressure level 0/+3 dB(A)
1~
Power (kW)
50Hz
0.55
≤58
0.75
≤59
1.1
≤64
1.5
≤64
2.2
-
When ordering spare parts, please give all the information on the
pump/motor rating plate.
1.2.2 Series specifications
Pump
family
Flow rate [m
3
/h]
(2-pole/ 50 Hz)
Number
of stages
E = gaskets EPDM
V = gaskets VITON
M = single-phase motor
T = three-phase motor
6 = 60 Hz
Without = 50 Hz
Manufacturer's key
8
1~
3~
3~
60Hz
50Hz
60Hz
≤60
≤58
≤60
≤61
≤59
≤61
≤67
≤59
≤62
≤68
≤64
≤68
-
≤64
≤68
MUH 3 02 E - M - 6 - XX/B
–15 °C to +90 °C
+40 °C
10 bar
50 Hz
1~230V (±10%)
3~230/400V (±10%)
3~220/380V (-10%) - 3~265/460V (+10%)
50 Hz
2900 RPM
see motor rating plate
IP 54
F
Connection diameters
Tapped port ND
Models
Suction
MUH 100
1" - (26-34)
MUH 300
1" - (26-34)
1/4
MUH 500
1"
- (33-42)
1/2
MUH 900
1"
- (40-49)
60 Hz
1~220V (-10%) - 1~240V (+6%)
60 Hz
3500 RPM
Discharge
1" - (26-34)
1" - (26-34)
1" - (26-34)
1/4
1"
- (33-42)
SALMSON 06/2016