Instructions for installation

Below we give the instructions for quali ed installers so that the
installation, setting and maintenance operations are performed
correctly and according to the regulations in force.
positioning
This appliance isn't connected to any scavenging devices of
combustion products. The appliance can only be installed and operate
in permanently ventilated rooms according to the local regulations in
force.
The natural ow of air must be direct through permanent holes made
in the walls of the room to be ventilated leading to the outside, or
through single or collective branched ventilation ducts.
The ventilation openings must have a e ective cross-section of at
least 100 cm
and must be protected against accidental blocking
2
(protection with metal grills or grids). There may also be an indirect
ow of air from rooms next to that where the appliance is installed,
as long as these rooms have direct ventilation, there is no re risk in
these rooms and they are not bedrooms.
The ow of air between adjacent room and the room where it is
installed must be free through permanent openings (which may be
obtained by making the gap between door and oor larger). In the
room where it is installed there must be a system for leading the
combustion fumes to the outside. This may be with a hood or an
electric fan which switches on when the appliance is switched on.

gas connection

The appliance must be connected to the gas supply or the cylinder
checking that it is adjusted for the type of gas available. The appliance
is set up to operate with the gas speci ed on the calibration label
placed both on the packaging and on the back of the appliance.
When the type of gas available does not correspond to that for which
the appliance is set up, replace the corresponding injectors (provided),
being careful to put on the new calibration label (provided) and
remove the old one. To perform these operations the quali ed
installer will follow the indications given in the "Adaptation to the
various types of gas" section. For safety operation make sure that
the supply pressure respects the values given in the "Table of burner
and injector characteristics". If the appliance is supplied with LP
cylinder gas, make sure that the cylinder pressure regulator conforms
to the local regulations in force.