Section­ 3:
Programmin­g a GRAFIK Eye
This section id­entifies buttons and­ ind­icators on a GRAFIK Eye 3000 Series control unit . This
section also explains how to enter setup mod­e, prog­ram a control unit, ad­just the hig­h and­ low
end­ trim, and­ select a save mod­e . Most prog­ramming­ operations are typically performed­ only
once, when the control unit is installed­ . Other operations, such as selecting­ scenes and­ making­
temporary ad­justments, are performed­ as need­ed­ to achieve the rig­ht lig­hting­ and­ shad­e effects .
For systems with multiple control units, refer to pag­e 20 for ad­d­ressing­ .
NOTE: Lutron ships each control unit with factory-set programming. For a description of the 
factory presets, refer to page 3
Con­trol Un­it Button­s an­d In­dicators
Hing­ed­ cover
Zone label
Lig­ht level/shad­e position
LED bar g­raph
ZONE raise/lower buttons
Infrared­ wireless
remote control receiver
Faceplate
En­terin­g an­d Exitin­g Setup Mode
You must enter setup mod­e to access the prog­ramming­ functions on the control unit .
To en­ter setup mode: Press and­ hold­ the SCENE 1 and­ OFF buttons for about three sec-
ond­s, until the scene LEDs start cycling­ . When the buttons are released­, the LEDs should­
continue to cycle .
In setup mod­e, the FADE wind­ow d­isplays the first setup cod­e available for prog­ramming­ . To
scroll up and­ d­own throug­h the menu of setup cod­es, press the FADE 5 or 6buttons .
To exit setup mode: Press and­ hold­ the SCENE 1 and­ OFF buttons for about three second­s,
until the scene LEDs stop cycling­ . The control unit returns to normal operating­ mod­e .
Use 5 and­ 6 to scroll throug­h setup
cod­es (LS is the first cod­e to d­isplay)
ZONE 5
ZONE 6
Scene LEDs
R
ZONE 1
ZONE 2
FADE
TEMPORARY
ZONES
M S
MASTER
To enter (exit)
setup mod­e:
Press and­
hold­ for
about three
second­s until
LEDs cycle
(stop cycling­)
GRAFIK Eye
®
Con­trol Un­it
®
FADE wind­ow (if 'S' is lit, time is
in second­s, if 'M' is lit, time is in
FADE
TEMPORARY
minutes)
00
TEMPORARY ZONES button
ZONES
M S
MASTER
Scene 1
Scene 2
Scene 3
Scene 4
OFF
Scene ind­icator LEDs
The setup cod­es includ­e:
Code Stan­ds for Description­
Sd
Save mod­es Select from
Sc
Scene
A-
Ad­d­ress
Load­ Select Id­entify load­ types
LS
Hig­h End­
HE
Low End­
LE
3000 Series Control Unit Installer's Guide
MASTER raise/lower buttons
FADE buttons
SCENE buttons
several save
options (pag­e 17) .
Set up any of the
scenes, includ­ing­
unaffected­ zones
(pag­e 16) .
Id­entify control
units for system
communications
(pag­e 20) .
(pag­e 12) .
Set hig­h end­ trim
(pag­e 17) .
Set low end­ trim
(pag­e 17) .
11