3.2 Approved UHP and RUN FLAT tyre demounting and mounting
procedure
For a detailed description of the UHP and RUN FLAT tyre mounting/demounting
procedure, please refer to the instructions in the manual prepared by WDK (German
Tyre Industry Association).
Correct procedure for demounting/mounting RUN FLAT tyres with valve
sensor
Follow this procedure if the sensor is on the tyre valve.
Demounting
1. Remove the valve plunger and let all the air go out of the tyre.
If necessary, remove the valve fixing nut and let the sensor fall into the tyre.
2. Place the sensor at 3 o'clock.
3. Lower the bead breaker disc and start the rotational bead breaking stage.
4. Lubricate the bead and continue rotational upper bead breaking until the sensor is
at 12 o'clock and not beyond.
5. Raise the bead breaker disc.
6. Move the sensor to 6 o'clock.
7. Push on the bead breaker disc and fit the clamp at 2 o'clock.
Manuale d'uso S 200