SICE S 200 Manual De Instrucciones página 156

Desmontadora automatica de neumaticos
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Bead breaker cylinder lacks force, fails to break beads and leaks air
Silencer plugged
Cylinder seals worn
After clamping, the tool head does not rise or rises too far from rim
Clamping plate not
adjusted
When the pole rotates, the horizontal and vertical arms move
Clamping plate not
adjusted
Faulty clamping plate
Clamping cylinders faulty
or not working.
Lack of supply to clamping
cylinders.
No air passage through valve
Faulty clamping plate.
Clamping plate not
adjusted.
Faulty pole tilting cylinder.
No air supply to cylinder.
Air leak from the valve.
Release valve incorrect setting. Adjust release valves.
Pressure gauge faulty or
damaged
156
Replace silencer.
- Replace seals.
- Replace bead breaker cylinder.
Adjust plate.
Adjust plate.
Replace plate.
Replace cylinders or seals.
Check the operation of controls and pneumatic circuit.
Replace the valve.
Vertical arm ascends under strain
Replace plate.
Adjust plate.
Automatic pole does not turn
Replace pole tilting cylinder.
Replace the valve.
Replace valve or pole tilting cylinder.
The automatic pole rotates violently or too slowly
Tyre pressure gauge needle fails to return to 0
Replace pressure gauge.
Manuale d'uso S 200

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido