Installation; Installing E-Pak 150 Dx/300 Dx/500 Dx; Indoor Installation; Outdoor Installation - Nederman E-PAK 150 DX Manual De Instrucciones

Ocultar thumbs Ver también para E-PAK 150 DX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
EN
E-PAK 150 DX/300 DX/500 DX
8
8.1
8.1.1
8.1.2
34
E-PAK 150 DX/300 DX/500 DX for maintenance while the others remain in
normal operation.
If the dust is abrasive, it may be necessary to use thick-walled (or rubber-
coated) material in bends and other exposed areas.
To avoid pressure losses, the duct system is to be as short as possible and
designed with two or more branches. Use larger diameters on the clean side to
reduce pressure losses.

Installation

Installing E-PAK 150 DX/300 DX/500 DX

WARNING!
Risk of personal injuries.
The outlet silencer and fan may reach high temperatures during normal
operation.
WARNING!
Risk of eye injuries.
Always stop the unit before looking into the outlet. The fan rotates at high
speed and debris and particles coming out of the outlet may cause eye injuries.
E-PAK 150 DX/300 DX/500 DX may be placed indoors or outdoors.
Consider the following when installing E-PAK 150 DX/300 DX/500 DX:
The foundation is to be level and hard, see Section '7.2.2 Foundation'.
Do not install E-PAK 150 DX/300 DX/500 DX close to heat sources or
hot surfaces.
Beware of hot air from the outlet.
Ensure that handling is convenient.
Ensure that emptying collected dust is convenient.
Ensure that service and maintenance are convenient.
In case of high relative humidity, do not expose
E-PAK 150 DX/300 DX/500 DX to freezing temperatures.
Do not place E-PAK 150 DX/300 DX/500 DX in direct sunlight.
NOTE!
Detailed information regarding installation of an explosion
suppression systems can be found in the suppression system manual. Work is
only to be carried out by certified personnel.

Indoor installation

Ensure that the room where the unit is to be installed is well ventilated.
NOTE!
Never seal a small room with a E-PAK 150 DX/300 DX/500 DX
installed completely!
In some conditions, the unit may draw air directly into the high-pressure fan.
This may cause a dangerous underpressure in the room if air cannot enter
freely. There are to be two openings for ventilation, at least 250×250 mm
(10"×10") in size. One is to be placed up high and the other one down low.

Outdoor installation

If installed outdoors, also consider the following:
Cover the top of the unit to protect it from snow, rain or falling debris.

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

E-pak 300 dxE-pak 500 dx

Tabla de contenido