Type of
Display
alarm
R0 - Insertion of a storage module contain-
ing over 100 stored remote controls
Warning: the
made automatically.
R3 - Storage module not detected
R4 - Storage module not compatible with
the control panel
R5 - No serial communication with the
storage module
R6 - Insertion of a specific storage module
for testing
P0 - No mains voltage
P1 - Microswitch voltage too low
B0 - Battery almost flat
A0 - Failure of test of safety sensor on con-
tact 6
A1 - Simultaneous safety sensor test on
contacts 6 and 8 failed
A3 - Failure of test of safety sensor on con-
tact 8
A7 - Incorrect connection of contact 9 to
terminal 41
A9 - Overload on output +LP-
Description
setting is
45
Operation
To save the system configurations on the
storage module, delete any stored remote
controls and bring the total to less than
100. Set
Insert a storage module.
Insert a compatible storage module.
Replace the storage module.
Check the control panel is powered cor-
rectly.
Check the line fuse.
Check the mains power supply.
Check the control panel is powered cor-
rectly.
Check battery voltage.
Replace battery.
Check the device SOFA1-A2 is working cor-
rectly.
If the supplementary SOF board is not insert-
ed, check the safety test is disabled.
Check the wiring and correct operation of
the safety sensor.
Check the device SOFA1-A2 is working cor-
rectly.
If the supplementary SOF board is not insert-
ed, check the safety test is disabled.
Check that terminal 1 and 9 are correctly
connected.
Check the device connected to output +LP- is
working properly.
.