15.7.1 Additional CC level parameters that can be configured
(available with
Display
CA - Setting the maintenance alarm
(factory setting - alarm deactivated: 0.0 00. 00).
You can set the required number of operations (regarding the partial operations counter)
for signalling the maintenance alarm.
When the set number of operations is reached, the alarm message appears on the
display
Example:
Setting the maintenance alarm after 700 operations (00) (07) (00)
→
OA - Selecting maintenance alarm display mode
00 - Visualisation on display (alarm message
01 - Visualisation on flashing light (with the automation idle, 4 flashes are
made and then repeated every hour) and on display (alarm message
02 - Visualisation on "open gate" indicator light (with the automation closed,
4 flashes are made and then repeated every hour) and on display (alarm
message
ZP - Reset of partial operations counter
→
2"
For correct functioning, you are advised to reset the partial operations counter:
- after maintenance work;
- after setting the maintenance alarm interval.
15.8 Second level menu - EM (Energy Management)
Display
PV - Solar panel power supply (panels not supplied)
ON - Enabled
OF - Disabled
ES - Energy-saving (disconnection of accessories connected to terminals 0-1
when the automation is in standby)
ON - Enabled (the red point on the right of the display flashes every 5 s. Output
+LP- is managed only for courtesy light).
OF - Disabled
Power supply disconnection mode is activated after 15 s with the gate closed,
or when the gate is idle and automatic closure is not enabled.
The automation resumes its normal operation when a command is received on
the radio board (6ZENRS-ZENPRS) or following a contact 30-5, 30-20.
WARNING: if you use accessories that need to remain powered even with
Energy Saving is enabled (e.g. LAN4 or GOPAV), set the jumper JR5 relating to
the slot used on power supply 0-30.
→