Display
R2 - Adjustment of thrust on obstacles and motor current during
closure. [%]
The control panel is fitted with a safety device which, when it detects
an obstacle:
- reverses the movement during closure operations outside the limit
area for detecting obstacles;
- stops the movement during closure operations within the limit area
for detecting obstacles.
The obstacle detection area during closure is determined by the type
of limit switch installed. If there is no limit switch, it is determined
according to the selection
00 - Minimum thrust
99 - Maximum thrust
15.4.1 Additional BA level parameters that can be configured
(available with
Display
DT - Adjustment of obstacle recognition time [s/100]
10 - Minimum
60 - Maximum
NB: the parameter is adjusted in hundredths of a second.
ST - Adjustment of start time [s]
0.5 - Minimum
3.0 - Maximum
TA - Adjustment of acceleration time during opening [s]
0.5 - Minimum
9.9 - Maximum
TQ - Adjustment of acceleration time during closure [s]
0.5 - Minimum
9.9 - Maximum
VM - Initial movement speed [cm/s]
00 - Minimum
15 - Maximum
TD - Adjustment of deceleration time during opening [%]
Regulates the slope of the deceleration ramp during opening.
10 - Minimum
99 - Maximum
TU - Adjustment of deceleration time during closure [%]
Regulates the slope of the deceleration ramp during opening.
10 - Minimum
99 - Maximum
OB - Adjustment of deceleration distance during opening. [cm]
Indicates the distance from the end of the opening stroke for the
start of the deceleration ramp.
05 - Minimum
99 - Maximum
EN
Description
→
.
→
enabled)
Description
28
Selections
available
50
Selections
available
40
2.0
2.0
2.0
05
75
75
60