Second Level Menu - At (Automatic Configurations) - entrematic Ditec ION4 Manual De Usario

Ocultar thumbs Ver también para Ditec ION4:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 212
15.2 Second level menu - AT (Automatic Configurations)
Display
DM - Direction mode
RT-opens to the right
LF-open to the left
H0 - Predefined setting, residential use 0
This selection loads predefined values for certain standard parameters:
AC - enabling of automatic closing
C5 - step-by-step/opening command operation
RM - remote control operation
AM - AUX plug-in board operation
SS - Selection of automation status at start-up
H1 - Predefined setting, residential use 1
This selection loads predefined values for certain standard parameters:
AC - enabling of automatic closing
TC - setting of automatic closing time
C5 - step-by-step/opening command operation
RM - remote control operation
AM - AUX plug-in board operation
SS - Selection of automation status at start-up
C0 - Predefined setting, condominium use 0
This selection loads predefined values for certain standard parameters:
AC - Enabling of automatic closure
TC - setting of automatic closing time
C5 - step-by-step/opening command operation
RM - remote control operation
AM - AUX plug-in board operation
SS - Selection of automation status at start-up
RD - Resetting of general settings (SETTINGS RESET)
AA - Activation of additional configurable parameters for each func-
tion of the main menu.
After activation you can scroll through the third level menus.
The third level menus are activated for 30 min.
EN
Description
2"
2"
2"
24
Selections
available
: 1-2
: Step-by-step
: Step-by-step
: Step-by-step
: open
: enabled
: 1 minute
: Step-by-step
: Step-by-step
: Step-by-step
: closed
: enabled
: 1 minute
: Opening
: Opening
: Opening
: closed