Display
TB - Permanent display of the internal control panel temperature
[°C]
WO - Setting of pre-flashing time on opening [s]
Adjustment of the lead time for the switch-on of the flashing light,
in relation to the start of the opening operation from a voluntary
command.
00 - Minimum
05 - Maximum
WC - Setting of pre-flashing time on closing [s]
Adjustment of the lead time for the switch-on of the flashing light, in
relation to the start of the closing operation from a voluntary com-
mand.
00 - Minimum
05 - Maximum
TS - Setting of renewal of automatic closing time after safety device
release [%]
00 - Minimum
99 - Maximum
VR - Setting of learning speed [cm/s]

16. Signals visualised on the display

i
NB: depending on the type of automation and control panel, certain visualisations may not
be available.

16.1 Display of automation status

NB: the automation status display mode is only visible with Display visualisation mode set
i
to 02.
Display
EN
Description
Automation closed
Automation closed Release door open
Automation open
Automation open Release door open
Description
40
Selections
available
00
00''
99
8