Connections and wiring
Charging status display
Open
Closed
Contactor monitoring
Open
Closed
7.5.1
Connection diagram
Fig. 7-18: Connection diagram X2
7.5.2
Connection example
The switch contact output can be used to switch off the charging station (dis-
connect the current) by means of an overriding disconnect solution.
290
Switch contact
Switch contact
Safety extra-low voltage Vcc < 50 V
F ≤ 0.5A current-limiting protective equipment
State of the charging station
Charging station not available.
Vehicle is connected, charging station not in
operation or faulty.
Charging station available.
Charging station is ready for operation and
no vehicle is connected.
State of the charging station
No error.
A switch contact of the contactor is stuck.