Configuration

8
Configuration
The basic configuration of the charging station is done using the DIP
switches.
8.1

DIP switch settings

Caution
Possible damage to the DIP switches!
The DIP switches are rocker switches and not slider switches. The DIP
switches must be pressed and must never be slid.
ON/OFF position of the rocker switches
The illustration shows the position of the rocker switches for the setting ON
and OFF
Information
Changes to the DIP switch settings only become effective after a restart of
the charging station!
To restart, press the "Service button" until the first beep (approx. 1 second)
or switch off the charging station for a short time via the line circuit breaker.
In the following tables, only the affected DIP switches are shown in the illus-
trations, others are not shown.
Control functions - DSW1
DIP switch
DSW1.1
294
Function
Using the external enable input X1 for starting
a charging process.
DSW1.1 ON: Charging enable when X1 is
closed. The charging enable is also dependent
on the RFID authorization. For details, see
Enable input
X1.
xChargeIn
Illustration
7.4
Installation manual V1.05