3
Chapter
Fig. 3: Test mode
on the IN4000
Standard safety
switches
Tab. 5: Electrical
input parameters
for the IN4000
Standard safety
switches
164
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8010934/WQ88/2013-01-15
Product description
3.5
Signal behaviour
At the TE input on the safety switch there must be a test
signal that meets the following conditions (cf. Fig. 3):
PSDI input (TE)
PSDI ouput (A)
The electrical input parameters are compatible with the
output parameters in compliance with EN 61131<2
(nominal current 0.1 A and nominal voltage 24 V):
Logical "1"
Logical "0"
Permissible test
pulse duration
If the actuating element is in the enable zone and
there is no sensor error, the test input signal is for-
warded to the output with the time delayed. The
output parameters are compatible with the para-
meters for the input in compliance with EN 61131<2
type 1 or 2:
$ 11 V, < 30 V
5V
'
1.0 ms
Operating Instructions
IN4000 Standard
T1 $ 50 ms
T2 $ 50 ms
T = 100...500 ms
Td = 1.0...1.5 ms
Input current 3 mA
Residual current
1 mA