Mounting; Mounting The In40-D0101K Safety Switch - SICK IN4000 Standard Manual Del Operador

Ocultar thumbs Ver también para IN4000 Standard:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4
Chapter
4

Mounting

WARNING
WARNING
WARNING
168
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8010934/WQ88/2013-01-15
Mounting
The IN4000 Standard safety system is only allowed
to be fitted by authorised specialist personnel.
Select the mounting location and the mounting
position of the safety switch such that
the safety switch is difficult for operators to access
when the protective device is open,
it must be possible to check and replace the safety
switch
Bypassing the inductive safety switch using simple
means must, as per EN 1088, be prevented by
installation features.
4.1
Mounting the IN40-D0101K safety
switch
The IN40-D0101K safety switch is not allowed to be
mounted flush in steel.
The IN40-D0101K safety switch can be installed in
copper, aluminium and brass either flush or surface
mounted; this type of mounting results in the
categorisation I1C40SP2 as per EN 60947<5-2.
The IN40-D0101K safety switch is not allowed
to be mounted flush in steel; this type of mounting
results in the categorisation I2C40SP2 as per
EN 60947<5-2.
Operating Instructions
IN4000 Standard

Publicidad

Tabla de contenido
loading

Tabla de contenido