Signal Behavior - SICK Direct IN4000 Instrucciones De Servicio

Ocultar thumbs Ver también para Direct IN4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
Chapter 3
Tab. 4: Output
parameters for the
IN4000 Direct
safety switch
WARNING
164
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Product description
3.5

Signal behavior

The safe state is the switched off state (unpowered
state: logical "0" on an OSSD).
If the actuating element is in the enable zone and there
is no sensor error, both output stages (OSSD) are
enabled (logical "1").
The output parameters are compatible with the pa-
rameters for the input as per EN 61 131K2 type 1 or 2:
Logical "1"
Logical "0"
If the actuating element is outside the enable zone, the
outputs are switched off (logical "0").
Cross-circuits between the two outputs will be
detected by the safety switch and result in the
shutdown of the outputs (OSSD).
Cross-circuits between the supply voltage and an
output will be detected and result in the shutdown of
the other output.
B 15 V
B 11 V
5 V
D
Operating instructions
IN4000 Direct
2 ... 15 mA
15 ... 30 mA
Residual current
0.2 mA
Pull-down current
typ. 30 mA
8012183/WI13/2013-01-15
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido