Operation
7.9 — Before Initial Start-Up
NOTE: This unit has been run and tested at the factory prior to shipment and does not require any break-in.
*
Operating the engine with the oil level below the ADD mark on the dipstick can cause
engine damage.
NOTE: This unit comes filled with 30 weight organic oil from the factory. Check the oil level and add the appro-
priate viscosity and amount if necessary.
7.9.1— Installation Wizard
Once activation is complete, the Installation Wizard immediately follows. It allows the user to input generator settings
upon power-up. See Figure 7-4.
The Installation Wizard will start every time power (both AC and DC) are removed and then re-applied.
"Generator"
"Ac ve"
ENTER
"Install Wizard"
"......."
ENTER
"Language"
"<- XXXXX ->"
"- English +"
"- Espanol +"
"- Francois +"
" Fuel Selec on"
"<- XX ->"
"- LP +"
"- NG +"
"Select Hour (0-23)"
"Select Minute (0-59)"
"Select Month (1-12)"
"Select Date (1-31)"
"Select Year (0-99)"
ENTER
"Install Wizard"
"Set Exercise"
ENTER
"Quiet Test Mode"
ENTER
"Select Frequency"
"Select Hour (0-23)"
"Select Minute (0-59)"
If Freq=Weekly or Biweekly
"Select Day"
"Sunday"
"Monday"
"Tuesday"
"Wednesday"
"Thursday"
"Friday"
"Saturday"
ENTER
"XXXXX"
"XXXXX"
Note: Finishes at status screen
36
This will only come up the rst me the generator is powered. If ESC is pressed to skip the
ac va on process, the ba
ry must be disconnected to allow ac va on again and this process
will reini
ze. If power is removed a
ac va on steps are skipped.
IF NOT YET ACTIVATED
Note1: Language only shows up
st me it is powered unless
enter is pressed to skip through
the install wizard
Note: Set Fuel Type
Note: Set Generator Time
"- NO +"
"YES +"
"- WEEKLY +"
- BIWEEKLY +"
MONTHLY +"
If Freq=Monthly
Select "1- 28"
Figure 7-4. Installation Wizard Menu
r a successful ac va on, the data is remembered and the
ENTER
ESCAPE
"Ac vate me (ENT) or"
"ESC to run in manual"
ENTER
Note1: Can run in MANUAL only
"To ac vate go to"
"www.ac vategen.com"
Note2: Must disconnect ba
3 sec delay
"Serial 1234567890"
wrong entry
"PASSCODE xxxxx"
Note: Low speed
exercise selec
n
Note: Set Exercise Time
Installation Guidelines for Air-Cooled Generators
"NOT ACTIVATED !"
if NOT ACTIVATED
ry
to allow ac va on again
"Wrong Passcode"
"Try Again"