2.2) Typical system

Figure 2 shows a typical system for automating a sectional door.
A
5
C
6
B
2
1
SPIN
2
Photocells
3
Photocells on post (fig. 3)
Figures 3 and 4 show typical installations of a protruding and non-protruding overhead door
!
For installations on overhead doors, the accessory SPA5 is required.
3
3

2.3) List of cables

Figure 2 shows the cables needed for the connection of the devices
in a typical installation; Table 6 shows the cable characteristics.
Table N°6: list of cables
Connection
A: Flashing light with aerial
B: Photocells
C: Key-operated selector switch
D: Primary sensitive edge
Note 1: A single 4x0.5mm
2
cable can be used instead of two 2x0.5mm
Note 2: Please refer to Chapter "7.3.2 STOP Input" in situations where there is more than one edge, for information about the type of con-
nection
Note 3: Special devices which enable connection even when the leaf is moving must be used to connect edges to the door.
2
2
4
4
Main edge
5
Flashing light with incorporated
aerial
Cable type
1 2x0,5mm2 cable
1 RG58 type shielded cable
1 cable 2x0,5mm
2
2 2x0,5mm2 cables (noea 1)
1 2x0,5mm2 cable (note 2-3)
D
B
B
6
Key-operated selector switch
7
PP function cord
8
Radio-transmitter
4
!
The cables used must be suitable for the type of installa-
tion. For example, an H03VV-F type cable is recommended for
indoor applications
Maximum length allowed
20m
20m (recommended less than 5m)
30m
50m
30m
2
cables.
1
7
8
5
GB
GB