Chapter 4,

Setting up the Multigas Detector

Power Systems

The Orion plus Multigas Detector is supplied with a NiMH battery
pack.
See TABLE 4-1 for nominal run times by battery type.
Table 4-1.
Approximate Battery Run Times (20°C)
BATTERY TYPE
HOURS (WITH PUMP)
NiMH
10
In colder temperatures, battery output may be severely reduced.

Battery Pack Removal

To remove the battery pack from the Orion plus Multigas Detector:
1. Remove the two screws from the bottom corner of the
battery pack.
2. Gently pull out the pack by lifting the bottom out of its recess;
then, slide it down.

Battery Charging (NiMH Battery Pack Only)

Charge the Orion plus Multigas Detector NiMH battery packs by using
the Orion plus Fast Charger supplied with the instrument.
Use of any charger, other than the Fast Charger supplied
with the instrument, may damage or improperly charge the
batteries.
The Orion plus Multigas Detector must be turned OFF, or the
battery pack must be removed from the instrument, prior to
charging.
The charger is capable of charging a completely depleted pack in
two hours in normal, room-temperature environments.
" CAUTION
4-1