Probe Filter

The MSA sampling probe contains a filter to:
block dust and dirt
block the passage of water.
If the probe tip is accidentally submerged in water, the filter
prevents the water from reaching the internal pump. The filter is not
designed to stop other liquids, such as gasoline or alcohols.

To Replace the Probe Filter

1. Grasp the probe handle by the base and guard.
2. Push the cap section toward the other two and turn clockwise.The
spring pushes the sections apart.
3. Grasp and spin the wand clockwise while pulling to disengage.
4. Remove the water trap filter (P/N 801582) and replace.

Storage

When not in use, store your Orion plus Multigas Detector in a safe,
dry place between -5
The Orion plus Multigas Detector with the NiMH rechargeable
battery pack can be stored on charge indefinitely.
After storage, always recheck instrument calibration before
use. During storage, sensors may drift or become inopera-
tive and may not provide warnings of dangers to the health
and lives of users.

Shipment

1. Remove battery pack before shipment. When returning the Orion
plus Multigas Detector for repairs, disconnect the normally used
battery pack from unit, and include it in the container.