7.3. Return delivery / storage
Lifting units that are sent back to the factory
must be cleaned to remove impurities and, if they
have been used with fluids that are harmful to
health, they must also be decontaminated.
For shipping, the parts must be packed in tear-
proof plastic bags of sufficient size in such a
manner that they are tightly sealed and leak-
proof. Furthermore, the packaging must protect
the lifting unit from damage during transporta-
tion. If you have any questions, please contact
the manufacturer!
For return delivery and storage please also refer
to the "Transport and storage" section!

7.4. Disposal

7.4.1. Protective clothing

The protective clothing and cleaning cloths must
be disposed of acc. to waste code TA 524 02 and
EC Directive 91/689/EEC, or acc. to local direc-
tives.
7.4.2. Product
Proper disposal of this product avoids damage to
the environment and risks to personal health.
• Use the services of public or private waste dis-
posal companies, or consult them for the disposal
of the product or parts thereof.
• For more information on proper disposal, please
contact your local council or waste disposal office
or the supplier from whom you obtained the
product.

8. Maintenance and repair

RISK of death due to electrocution!
There is a risk of fatal injury from electric
shock when working on electrical equipment.
With all maintenance or repair work, the
lifting unit must be disconnected from the
mains and secured against being switched
on again without permission. Damage to the
power supply cable may only be rectified by a
qualified electrician.
DANGER – explosive atmosphere!
An explosive atmosphere can form within the
collection reservoir. If the collection reser-
voir is opened, then this can form inside the
operating space. There is a risk of fatal injury
due to explosion! Take appropriate counter-
measures (e.g. appropriate replacement of
air) to avoid an explosive atmosphere in the
operating space!
The end-user is responsible for defining a
corresponding explosion zone. Observe the
following:
48
MAINTENANCE AND REPAIR
• Switch off the lifting unit in accordance with the
chapter "Decommissioning/disposal".
• After maintenance or repair work, the lifting unit
must be put back in operation in accordance with
the "Commissioning" chapter.
Note the following:
• All maintenance and repair work must be carried
out by Wilo customer service, authorised service
workshops or trained specialists with the greatest
of care and in a safe workplace. Proper protective
clothing is to be worn.
• This manual must be available to and observed
by the maintenance staff. Only maintenance
and repair work described in this manual may be
carried out.
Any other work and/or alterations to the
construction must only be carried out by Wilo
customer service!
• When working in pump chambers, it is essential
to comply with the corresponding local protective
measures. A second person must be present for
safety reasons.
• Lifting equipment in perfect technical condition
and officially approved load-bearing equipment
must be used for transporting the lifting unit. No
lifting forces greater than 1.2 times the pump
weight may be applied! The max. permissible
bearing capacity must never be exceeded!
Make sure the lifting gear, wire rope and safety
devices of the lifting equipment are in perfect
working order. Work may only commence if
the lifting equipment has been checked and
found to be in perfect working order. If it is not
inspected, fatal injuries may result!
• Electrical work on the lifting unit must be carried
out by a qualified electrician. Defective fuses
must be replaced immediately. These must never
be repaired! Only fuses for the specified electric
current and of the specified type may be used.
• If flammable solvents and cleaning agents are
used, naked flames and smoking are prohibited.
• Lifting units that circulate fluids that are haz-
ardous to health or come into contact with such
fluids must be decontaminated. In addition, make
sure that no gases that are hazardous to health
form or are present.
• If injuries are caused by fluids or gases that are
hazardous to health, apply the first-aid measures
specified on the notice at the working premises
and notify a doctor immediately!
• Operating fluids (e.g. oils, lubricants, etc.) should
be collected in suitable containers and disposed
of properly. Also comply with the information in
section 7.4 "Disposal"!
• Use only original parts from the manufacturer.

8.1. Basic tool equipment

• Torque wrench ¼", 1-25 Nm
• Socket wrench: 7 / 10 / 13 mm
• Hexagon socket wrench: 6 mm
• Torque wrench 3/8", 10-100 Nm
• Socket wrench: 19 / 24 / 30 mm