Chapter5
Page24
5.2.2
Adjustments OTA/U-BW
INFO
Adjusting the stop edges
Figure 11
The stop edges are adjusted correctly when after the adjustment the trays are located centrally on the stack-
ing platform and sideways have a distance of 0.19'' (5 mm) to the stop edges. The trays rest directly against
the vertical plastic stop beads and are flush at the front edge of the platform.
The adjustment mechanism for the stop edges is located below the stacking platform.
Figure12
To adjust the sideways stop edges, proceed as follows:
§
Carefully tilt the device so that it rests on the push bars.
§
Loosen both cylinder head screws with internal hexagon (1), but do not remove them completely.
Therefore use a hexagon wrench SW 8 mm.
§
Adjust the lateral stop edges to the desired level.
§
Screw the socket head screw tight.
To adjust the front stop edge, proceed as follows:
§
Unscrew the two counter nuts (2) from the setscrews. Therefore use an open-end wrench SW 17
§
Loosen the setscrews, but do not remove them completely. Therefore use a hexagon wrench 0.19'' (5
mm).
§
Pull out the front stop to the desired length.
Tray dispenser
OTA/47–36 | OTA/53–37 | OTA/58-33 | OTA/53–37 S | OTA/U-BW | OTA-E/BA-4xGN | TAG-1/53-37 | TA-2/53-37 | EBS-T/53-37
Required tools
You need the following tools for changing the stop edge of the cover of the
spring case:
Open-end wrench SW 17,
Philipps screwdriver size 1,
Screwdriver size 7 (chisel width 6-7 mm and thickness 0.8–1.0 mm)
hexagon wrench SW 5 and 8 mm,
knife
Adjust stop edges
Stacking platform (bottom view)
Adjustment of the open Tray Dispensers
Operation
4330041_A2