Always switch Off the circuit to be tested before connecting
the multimeter to the circuit
Warning : connect the leads to the multimeter and connect in series to the
circuit
- the red lead to the + terminal up to 400mA
- the red lead to the 10A terminal , from 400mA to 10A
Place the selector switch to the A or mA ammeter function.
Press the DC/AC button to select DC or AC.
Switch On the circuit to be tested so that it is live
Automatic range selection : read the measured value
If necessary, press the following buttons
- RANGE to manually select the ranges
- MIN.MAX to read the min or max values
-
to light the display
DC CURRENTS
A DC
Voltage (2)
drop
Digital
resolution
Bargraph
resolution
Accuracy
Protection (3)
DC and AC CURRENTS
(C.A 5220 G only)
40 mA
600 mV
10 µA
1 mA
± 1.5 % reading ± 1 count
Fuse 0.4 A HBC
400 mA
4,5 V
100 µA
10 mA
27
10 A (1)
600 mV
10 mA
1 A
± 1.5 % R
± 2 counts
Fuse 12 A HBC