Descargar Imprimir esta página

SICK CLV69 Serie Instrucciones De Servicio página 75

Escáneres de códigos de barras

Publicidad

Wire switching outputs "External output 1 and 2" of the CLV69x on the CDB650-204 connection module
CLV69x
Serial Aux
"External
output 1,
(RS-232)
output 2"
Specifications of the switching outputs "External output 1 and 2"
PNP switching to supply voltage U
Logic
(default: no function,
logic: not inverted [active high])
Properties
–Short-circuit protected + temperature protected
– Not electrically isolated from U
Electrical
0 V ≤ U
≤ U
*
a
IN
values
Guaranteed:
(U
* −1.5 V) ≤ U
IN
Functional allocation for switching outputs via
SOPAS-ET configuration software.
Figura 74: Cableado de salidas conmutadas "Entrada externa 1 y 2"
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso
CDB650-204
CMC600
CLV69x
CDB650-204
Output
Name
External output 1
EXT. OUT 1
External output 2
EXT. OUT 2
*
IN
*
IN
≤ U
* in the case of I
≤ 100 mA
a
IN
a
U
*
IN
Shield
6
Name
Z
GND
GND
22
Terminal Z
23
24
The CLV69x releases the output states of its logical
outputs "External output 1 and 2" via its serial Aux
interface.
Via the connecting cable, the CMC600 automatically
accepts the statuses in a software-controlled manner
and transfers them to its physical outputs "EXT. OUT 1
and 2" in the CDB650-204.
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
INSTALACIÓN ELÉCTRICA
Load (e.g. PLC)
U
a
In the case of
inductive load:
Discharge wiring:
apply free running
diode directly to
the load!
6
75

Publicidad

Capítulos

loading