Wire "Result 1 and 2" switching outputs of the CLV69x in the CDM420-0006 connection module
CLV69x
U
V
Result X
GND
CLV69x
CDM420-0006
Result X
Pin Y1
Pin Y2
Name
Result 1
13
12
Result 1
Result 2
14
13
Result 2
Characteristic data of "Result 1 and 2" switching outputs
Switching
PNP switching to supply voltage U
CLV69x default settings:
behavior
Result 1: device ready (static), logic: active high
Result 2: good read, 100 mm, logic: active high
Properties
–Short-circuit protected + temperature protected
–Not electrically isolated from supply voltage (+24 V*)
Electrical
0 V ≤ U
≤ U
a
V
values
Guaranteed:
(U
− 1.6 V) ≤ U
V
Functional assignment for switching outputs
via SOPAS-ET configuration software!
Figura 85: Cableado de salidas conmutadas "Result 1 y 2"
86
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
1)
Adapter cable
2)
2
.
.
.
Y1
1
3
12
2
11
13
4
1
5
16
14
10
6
9
17
15
8
7
M12 male connector,
17-pin, A-coded
Terminal Z
14
15
V
≤ U
at I
≤ 100 mA
a
V
a
CDM420-0006
1
+24 V* (U
)
V
Shield
5
Y2
Name
5
GND
13
GND
10 5
1
6
15
11
D-Sub-HD
female connector, 15-pin
1) Dependent on type
For CLV69x-xxx0 (without heating):
No. 2049764 (0.9 m)
No. 2055419 (2 m)
No. 2055420 (3 m)
No. 2055859 (5 m)
For CLV69x-xxx1 (with heating):
No. 2061480 (2 m)
No. 2061605 (3 m)
No. 2061481 (5 m)
2) Pin 2 in CLV69x-xxx1
(with heating) not connected
Load (e.g. PLC)
Z
U
a
With inductive load:
Sweep-out circuit:
Attach a freewhee-
ling diode directly
to the load.
8025632/131W/2019-03-06 | SICK