Wire supply voltage for CLV69x-xxx0 in the CDM490-0001 connection module
1
2
Max.
F
2 A
5
DC 18 V ... 30 V
S1 : POWER
ON
OFF
U
= DC 18 ... 30 V
V
+) If no switching inputs and outputs of the CLV69x are used, cable 2 does not have to be used
1 "HOST/AUX/I/O" connection
2 "I/O" connection
U
= DC 18 V ... 30 V at terminal +24 V =
V
U
at terminal +24 V* after switch S1, protected by internal fuse F
V
Switch S1:
ON:
supply voltage U
to CDM490-0001 and CLV69x.
U
(+24 V*) can also be engaged on terminal 29 of the basic
V
card as well as on terminal 51 ... 53 of the I/O card.
OFF:
CDM490-0001 and CLV69x separated from supply voltage.
Recommended position for all connection types.
Figura 90: Tensión de alimentación cableada para CLV69x-xxx0 (sin calefacción)
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso
CDM490-0001
D-Sub-HD
(basic card)
+24 V*
+24 V
F
GND
S1
+24 V*
POWER
Shield
Shield
GND
D-Sub-HD
(+24 V) switched via fuse as U
V
INSTALACIÓN ELÉCTRICA
Cable 1, e.g. no. 2020302 (3 m)
10 5
1
6
6 1
5
10
1
11
15
15
11
1
1
.
.
.
.
.
.
.
.
.
5
5
1
1
.
.
.
.
.
.
.
.
.
5
5
2
10 5
1
6
6 1
5
10
11
15
15
11
Cable 2, e.g. no. 2020302 (3 m)
(+24 V*)
V
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
CLV69x-xxx0
(without heating)
U
V
U
V
GND