INSTALACIÓN ELÉCTRICA
Wire RS-232 data interface of the CLV69x in the CDM490-0001 connection module
CLV69x
1
9
TxD
7
RxD
5
GND
RS-232
D-Sub-HD
1 "HOST/AUX/I/O" connection
Figura 91: Interfaz de datos serie RS-232 cableada
Wire RS-422 data interface of the CLV69x in the CDM490-0001 connection module
CLV69x
1
8
TD+
9
TD‒
6
RD+
7
RD‒
5
GND
RS-422
D-Sub-HD
1 "HOST/AUX/I/O" connection
Figura 92: Interfaz de datos serie RS-422 cableada
92
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
Cable 1, e.g.
No. 2020302 (3 m)
9
T‒/TxD
7
R‒/RxD
5
GND
.
GND
.
.
Shield
S2 : RS 485
10 5
1
6
6 1
5
10
ON
OFF
15
11
11
15
Cable 1, e.g.
No. 2020302 (3 m)
8
9
6
7
5
.
.
.
S2 : RS 485
10 5
1
6
6 1
5
10
ON
OFF
11
15
15
11
S3: Term 422
Set to ON if termination of the
RS-422 receiver in the CLV69x is
necessary to improve the signal-to-in-
terference ratio on the cable.
CDM490-0001
(Basic card)
S2
34
485
OFF
35
36
6
S3: Term 422
ON
OFF
CDM490-0001
(Basic card)
S2
T+
24
OFF
T‒/TxD
34
S3
R+
25
OFF
R‒/RxD
35
120 Ω
GND
36
GND
Shield
6
S3: Term 422
ON
OFF
Host
RxD
TxD
GND
RS-232
Host
RD+
RD‒
TD+
TD‒
GND
RS-422
8025632/131W/2019-03-06 | SICK