Descargar Imprimir esta página

SICK CLV69 Serie Instrucciones De Servicio página 83

Escáneres de códigos de barras

Publicidad

Wire CLV69x in the CDM420-0006 connection module for SICK CAN SENSOR network
Adapter cable
CLV69x
CAN 1,
among others
(Master)
GN = 63
Branch line
GN = 01
Adapter cable
CLV69x
CAN 1,
among others
(Slave)
GN = 02
Adapter cable
CLV69x
CAN 1,
among others
(Slave)
GN = 03
Adapter cable1)
CLV69x
CAN 1,
among others
(Slave)
(max. 32 participants)
Figura 82: Cableado de la interfaz CAN
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso
CDM420-0006
Switch
S4 (TermCAN):
R‒/RxD
ON
OFF
1)
S2 (RS485):
ON
T‒/TxD
OFF
21
22
23
6
CAN
21
22
23
6
1)
31
32
33
7
CDM420-0006
CAN
21
22
23
6
1)
31
32
33
7
CDM420-0006
CAN
21
22
23
6
CDM420-0006
INSTALACIÓN ELÉCTRICA
Ethernet
Ethernet
Ethernet (Host Port)
Serial host interface
RS-422
R+
25
TD+
35
TD‒
T+
24
RD+
34
RD‒
GND
GND
26
Shield
7
Connection and looping of the supply
Switch
voltage and connection of the read
S4 (TermCAN):
cycle sensor, e.g. to host, is neglected
ON
here.
OFF
Switch
S4 (TermCAN):
CAN_H = CAN1_H CLV69x
ON
OFF
CAN_L = CAN1_L CLV69x
S4 (TermCAN = TermCAN1)
1) Dependent on type
For CLV69x-xxx0 (without heating):
No. 2049764 (0.9 m)
Switch
No. 2055419 (2 m)
S4 (TermCAN):
No. 2055420 (3 m)
ON
No. 2055859 (5 m)
OFF
For CLV69x-xxx1 (with heating):
No. 2061480 (2 m)
No. 2061605 (3 m)
No. 2061481 (5 m)
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
RS-232
Host
Host
TxD
RxD
GND
6
83

Publicidad

Capítulos

loading