Setting process for vehicles with and without an information display (CANDIS (o)):
– Enter the three-digit parameter number and press the Set key (22) to confirm.
– The operating hours are still shown in the information display (CANDIS (o)). When
the display changes, you can end the setting process by pressing the o key (27)
and then start again.
– Enter or change the setting as shown in the parameter list and press the Set key
(23) to confirm.
If an illegal value is entered, the LED (22) in the o key (27) flashes red. Enter
NOTICE
the parameter number again and then enter or change the setting.
Repeat the process to enter additional parameter settings. When you have finished,
press the o key (27).
The following parameters can be entered:
Code lock parameter list
No.
Code lock
000 Change master code
The length of the master
code (4 to 6 digits) also
determines the length of
the operator code (4 to 6
digits). If operator codes
have been programmed,
only one new code of the
same length can be
entered. A change in the
length of the code
requires all operator
codes to be deleted first.
001 Add operator code (600,
max.)
E 38
Function
000000 - 999999
000000 - 999999
Range
Standard
Setting value
0000 - 9999
or
00000 - 99999
or
0000 - 9999
or
00000 - 99999
or
Notes
Setting
Procedure
value
7295
(LED 24 flashes)
Enter the
current code
Confirm (Set)
(LED 25 flashes)
Enter a
new code
Confirm (Set)
(LED 26 flashes)
Enter new code
again
Confirm (Set)
2580
(LED 22 flashes)
Enter a
code
Confirm (Set)
(LED 23 flashes)
Enter the
code again
Confirm (Set)