7
Discharge indicator (LEA) (
Once the vehicle has been enabled with the key
switch or CANCODE, the battery charge level is
displayed.
The colors of the LED (32) represent the following states:
LED color
green
orange
red
NOTICE
If the LED lights up red, load units can no longer be lifted. The "Lift" function
is not enabled again until the charge level of the connected battery reaches
a minimum of 70%.
If the charge level status when the vehicle is switched on is at least 70% of the charge
level of a fully charged battery, the display is reset to 100%. The display falls in 10%
increments according to the charge level. The charge level display drops by a
maximum of 10% in 3 minutes.
The charge level display cannot rise again while the truck continues to be operated.
The charge level display is reset to 100% when the battery type is set.
If the LED flashes red and the vehicle is not ready for use, contact the manufacturer's
service organization. The red flashing light is a vehicle control fault code. The flashing
sequence indicates the type of fault.
Error messages
Error messages (message number displayed as a flash code) are output via the LED
of the connected information display. The tens position should be displayed at a
frequency of 1 Hz and the units position at a frequency of 2 Hz. A 2 second pause
should be inserted when switching between the units and the tens position.
E 44
t
)
Residual capacity of standard battery
Residual capacity of maintenance-free battery
Residual capacity of standard battery
Residual capacity of maintenance-free battery
Residual capacity of standard battery
Residual capacity of maintenance-free battery
32
40 - 100%
60 - 100%
Value
20 - 30%
40 - 50%
0 - 30%
0 - 40%