9

Final de-commissioning, disposal

NOTICE
Final, proper decommissioning or disposal of the truck must be performed in
accordance with the regulations of the country of application. In particular,
regulations governing the disposal of batteries, fuels and electronic and
electrical systems must be observed.
10

Troubleshooting

All problems and results of operator error are shown in the operator display. Follow
the instructions on the operator display.
If needed, restart the vehicle. Turn off the EMERGENCY STOP switch and turn it on
again.
If the vehicle does not start, note the following:
Fault
Vehicle will
not start
NOTICE
If the industrial truck cannot be restored to working order by carrying out the
"remedies" or if a fault or defect appears on the display unit along with the
relevant error number, please contact the manufacturer's service
organization.
Further fault correction can only be carried out by qualified manufacturer
service personnel. The manufacturer's service organization is able to provide
customer service support specifically for situations like these.
Please provide the following information to customer service personnel in
order to enable them to deal with the problem effectively and quickly:
- Serial number of the industrial truck
- Error number as indicated on the display unit (if there is one)
- Description of error
- Current location of the industrial truck.
Possible cause
Battery connector not
plugged in / battery cable split
EMERGENCY STOP switch
pressed.
Turn switch latch to position
"0"
Faulty fuse
Remedy
Check battery connector and plug in if
necessary / check battery cable
Unlock EMERGENCY STOP switch.
Turn switch latch to position "I"
Check fuses
G 19