Descargar Imprimir esta página

Control Unit Buttons And Indicators; Enter And Exit Setup Mode - Lutron GRAFIK Eye 4000 Serie Manual De Instalación

Ocultar thumbs Ver también para GRAFIK Eye 4000 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Section 4:
Programming a GRAFIK Eye
NOTE: For slider units, this section is covered in the Addendum included with those units.
This section identifies buttons and indicators on a GRAFIK Eye 4000 Series control unit. This section also explains 
how to enter setup mode, program a control unit, and select a save mode. Most programming operations are 
typically performed only once, when the control unit is installed. Other operations, such as selecting scenes and 
making temporary adjustments, are performed as needed to achieve the right lighting and shade effects.
For systems with multiple control units, refer to page 17 for addressing.
NOTE: Lutron ships each control unit with factory-set programming. For a description of the factory presets, refer to 
page 3.

Control Unit Buttons and Indicators

Hinged cover
Zone label
Light level/shade position   
LED bar graph
ZONE raise/lower buttons
Infrared wireless   
remote control receiver
Faceplate

Enter and Exit Setup Mode

You must enter setup mode to access the programming functions on the control unit.
To enter setup mode: Press and hold the SCENE 1 and OFF buttons for about three seconds, until the scene 
LEDs start cycling. When the buttons are released, the LEDs should continue to cycle. 
In setup mode, the FADE window displays the first setup code available for programming. To scroll up and down 
through the menu of setup codes, press the FADE 5 or 6buttons.
To exit setup mode: Press and hold the SCENE 1 and OFF buttons for about three seconds, until the scene LEDs 
stop cycling. The control unit returns to normal operating mode.
Use 5 and 6 to scroll through setup codes 
(LS is the first code to display)
ZONE 5
ZONE 6
Scene indicator 
LEDs
R
ZONE 1
ZONE 2
FADE
TEMPORARY
ZONES
M S
MASTER
To enter (exit)  
setup mode:
Press and hold 
for about three 
seconds until 
LEDs cycle (stop 
cycling)
Control Unit
®
FADE window (if 'S' is lit, time is in seconds, 
FADE
TEMPORARY
if 'M' is lit, time is in minutes)
00
TEMPORARY ZONES button
ZONES
M S
MASTER
Scene 1
Scene 2
Scene 3
Scene 4
OFF
Scene indicator LEDs
The setup codes include:
Code
Stands for
Sd
Save modes 
Sc
Scene 
A-
Address 
LS
Load Select 
GRAFIK Eye
 4000 Series Control Unit Installer's Guide     15
®
MASTER raise/lower buttons
FADE buttons
SCENE buttons
Description
  S elect from 
several save 
options (page 21).
  S et up any of the 
scenes, including 
unaffected zones 
(page 20).
  I dentify control 
units for system 
communications 
(page 16).
  I dentify load types 
(page 15).

Publicidad

Solución de problemas

loading

Este manual también es adecuado para:

Grafik eye 4100Grafik eye 4500