Operating instructions
IN4000 Direct
8012183/WI13/2013-01-15
Subject to change without notice
Technical specifications
Parameters
Operating data
Response range/
enable zone
4)
IN40-E0101K
5)
IN40-E0109K
Safe switch off
distance
4)
IN40-E0101K
5)
IN40-E0109K
Response times
Response time to
safety request
Response time on
approach to near
range zone (non
safety-related zone)
Response time on
approach to the
enable zone (enable
time)
4)
Applies in the entire temperature range, referred to a
reference plate 45 × 45 × 1 mm³ in accordance with
IEC 60 947-5-2 (FE360 = ST37K).
5)
Applies in the entire temperature range, referred to a
reference plate 60 × 60 × 1 mm³ in accordance with
IEC 60 947-5-2 (FE360 = ST37K).
6)
The outputs are switched off during this time (logical "0").
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Value
Minimum
Typical
10 mm
4 mm
> 30 mm
> 45 mm
100 ms
GB
Chapter 9
Maximum
15 mm
20 mm
6)
50 ms
100 ms
200 ms
183