Fault diagnosis
7.2

Troubleshooting

Problem
Possible cause
No LED
No supply voltage
indication
• Power
• Undervoltage
LED does
• Overvoltage
not flash.
• Sensor
does not
switch.
The sensor
Sensor has been
does not
placed in the safe
switch, also
state (logical "0").
not after
Cause:
removal of
• Cross-circuit
actuation
and
renewed
actuation.
• Cross circuit error
• Error detected in
between the
outputs OUT1 and
OUT2
between one of
the outputs and
the supply voltage
the sensor.
Operating instructions
IN4000 Direct
Rectification of the
error
Switch the voltage
supply on.
Check supply
voltage (see 9.1
"Data sheet" on
page 181).
Switch the voltage
supply off and
back on again.
Test the
connections and
their wiring.
Test the
components
connected, e.g.
the PLC.
Rectify possible
cross-circuits.
Replace the
device.