4.2
Zero sequence
The zero sequence is used for determining the „Offset" of the
currently used claming device.
Call of the program zero sequence via the start monitor and the
functional key F2.
The currently selected claming device is displayed on the monitor.
The corresponding key is represented in light grey and is not
active.
Before starting the zero sequence, select the corresponding
claming means, the centering sequence, the universal clamping
device or the motorcycle clamping device via the functional keys
F1, F2 or F3.
Selection of the claming device
F1 Centring clamping device
F2 Clamping device for motorcycles
F3: Universal clamping device for closed rims.
Is mainly used for vehicles of French manufacturers
As an orientation aid, during the zero sequence, the current axis
position is displayed in the lower left-hand corner of the monitor.
Within one revolution, the display varies between 0 and 255.
1 689 979 918N
13.01.2010
4.2.1
Zero sequence operational sequence
Remove cone and hand wheel from the clamping
device if the clamping device for centering is used.
If any other clamping device is used, remove all easily
movable parts or torque them.
Start the zero sequence by actuating the start key.
When this measuring sequence is terminated, the symbol for the
clamping device which was selected before the zero sequence
will be displayed in the status strip.
The symbols for the basic settings, the calibration, wheel data
detection and measuring sequence are displayed in the menu line
of the main monitor.
When actuating the start key, the program automatically switches
over to the balancing mode. The measured imbalances of the
clamping device are saved and will continue to be saved after the
machine has been switched off.
Function key assignment after executing the zero sequence
F1 Basic settings:
Change-over to the monitor „Basic settings"
F3 Calibration run: Machine adjustment
F4 Wheel data:
Change-over to the „Wheel data detection"
F5 Balancing:
Change-over to the start monitor for the
balancing process
29