Factory Calibration; Recalling Of The Calibration Menu; Flange Calibration; Calibration Of Electronic Calliper Gauge/Measurement Arm - Bosch WBE 4420 Instrucciones De Reparacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
30 | WBE 4420 | Settings and Service
3.4

Factory calibration

i
We recommend carrying out the factory calibration
during software updating, replacement of the
pick-up, of the measurement unit or of the board,
following the sequence below:

1. Flange calibration

2. Calliper gauge/measurement arm calibration

3. Calibration with sample weight.

!
At the end of every calibration carry out a control
measurement.
3.4.1

Recalling of the calibration menu

1. From the "Settings and Service" menu select
Calibration and confirm by pressing <OK>.
2. Enter password: <z> <u> <v>.
"
The calibration menu is displayed.
Calibration with sample weight.
Flange calibration
Back to main page.
Calliper gauge and measurement arm calibration
3.4.2
Flange calibration
i
Follow the instructions for the standard calibration
(see chap. 5.4.2).
3.4.3
Calibration of electronic calliper gauge/
measurement arm
i
Follow the instructions for the standard calibration
(see chap. 5.4.3).
|
1 695 655 424
2010-04-30
3.4.4
Calibration with sample weight
i
Keep to the indications displayed on the monitor.
1. Select Calibration with sample weight and confirm
by pressing <OK>.
« Calibration is started.
2. Bring the calliper gauge on the flange.
3. Bring the calliper gauge back to stand-by position
4. Press <START> or close the wheel protection cap.
« Measurement is started.
5. Apply the sample weight on the internal side of the
flange.
6. Press <START> or close the wheel protection cap..
« Measurement is started.
7. Remove the sample weight from the internal side
of the flange and apply it on the external side (12
o'clock).
8. Press <START> or close the wheel protection cap.
« Measurement is started.
9. Turn the flange until the weight is in 12 o'clock
position.
10. Press <OK>.
"
Calibration is completed.
i
The performed calibration is automatically and
permanently saved.
i
After having carried out factory calibration with
sample weight, access the standard calibration menu
(see chap. 5.4.1) and perform the calibration with
wheel and sample weight (see chap. 5.4.4).
Robert Bosch GmbH

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido