Running Welding Data Recording
Release the clamping arm at the end of the welding seam.
Recording ends as soon as the force falls below the set threshold value.
The next log file is prepared. In the status line (35), the file number of the new file is displayed alternately in the
network voltage display and the
Finishing welding
• Switch off the drive after the welding tasks are completed.
• Switch off the heating.
• Wait until the
symbol is no longer flashing.
• Switch off the device using the main switch.
Displaying Alarm Value Transgressions in the Welding Data Record During the

Welding Process

When "Alarm" is activated, the speed, temperature, and force are continuously monitored during the welding
process to check that these values remain within the defined alarm values. If an alarm value is exceeded, this is
indicated on the device.
• If a set alarm value is exceeded during the welding process, this is
shown in the display when alarm value monitoring is switched on.
(See Chapter "Displaying Alarm Value Transgressions in the
Welding Data Record During the Welding Process")
In such cases, make changes depending on the situation
(see Chapter "Speed and Temperature Setting During Welding"
in the device operating instructions).
symbol flashes.
Speed:
• If the speed falls below the lower tolerance value,
- the speed display will flash.
- a "<" symbol will be displayed in front of the actual value.
- a warning signal will sound if the acoustic alarm is activated.
• If the speed exceeds the upper tolerance value,
- the speed display will flash.
- a ">" symbol will be displayed in front of the actual value.
- a warning signal will sound if the acoustic alarm is activated.
Temperature:
• If the temperature falls below the min. alarm value,
- the temperature display will flash.
- a "<" symbol will be displayed in front of the actual value.
- a warning signal will sound if the acoustic alarm is activated.
• If the temperature exceeds the max. alarm value,
- the temperature display will flash.
- a ">" symbol will be displayed in front of the actual value.
- a warning signal will sound if the acoustic alarm is activated.