DMSP/MAS
8
Maintenance and care
Inspect DMSP/MAS at the following intervals for signs of aging.
Inspection
Inspection
1)
interval
Every 500,000
Visual inspection Stress cracks, blisters and other
switching cycles
Audible check
1) The inspection intervals are reduced by extreme ambient conditions (e.g. strong sunlight, high air humidity, high ozone stress)
Tab. 3
Clean DMSP/MAS as needed with water or soap suds (max. 60 °C).
9
Disassembly and repair
For signs of aging (è 8 Maintenance and care):
Exhaust the complete system and product.
Replace DMSP/MAS completely.
Due to the safety requirements for the connection between the contraction membrane and connecting
flange, a repair is not permissible.
10
Disposal
Dispose of packaging and DMSP/MAS at the end of its useful life through environmentally friendly
recycling in accordance with applicable specifications.
11
Accessories
è www.festo.com/catalogue
Festo – DMSP/MAS – 1508e English
Possible signs of aging
damage to the surface
Exposed fibres
Audible air leakage
Action
Replace DMSP/MAS.
Inspect pneumatic
connection.
Replace DMSP/MAS.
25