Install Backsplash (Optional) - Broan best PIK33 Instrucciones De Instalación

Ocultar thumbs Ver también para best PIK33:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. INSTALL BACKSPLASH (OPTIONAL)

It is recommended to install the backsplash before the custom hood insert. The custom hood will cover the backsplash top
mounting screws. In order to be able to install the backsplash, make sure you have at least 18'' clearance between bottom of
custom hood and range control panel or cooktop. (See instructions packed with backsplash.)
4. CUSTOM HOOD PREPARATION
When building a custom hood, always follow all applicable construction codes and standards.
The custom hood frame must be sized to the shape and total weight of the insert assembly. Refer to the table below for total
weight of the insert, according to the type of blower choosen.
I
P5
NSERT MODEL
WITH
PIK33
PIK45
Start with the custom hood base, because its position will determine the
height of the insert. We recommend the base of the custom hood should be
3/4-inch thick plywood. If an optional custom hood liner will be installed, we
recommend the sides and front of the custom hood to be 3/4-inch thick,
assuming standard cabinet widths. If the optional custom hood liner will not
be installed, the custom hood side and front thickness is at the installer's
discretion.
Run power cable to installation location. Stub out a 4-foot length of electrical
cable below the custom hood.
If the WCPI optional remote control will be installed, run electrical cable
from the insert to the remote control location. Stub out a 6-inch length from
the remote control wall location. Refer to the remote control installation
instruction.
5. SUGGESTED CUSTOM HOOD INTERNAL FRAMEWORK
The mounting holes for the 2 top stud supports are located at 11
from the insert base. The on center distance between the 2 studs is
30¼" for the PIK33 insert model and 42¼" for the PIK45 insert model.
The mounting holes for the rear stud support are located at 1½" up from
the insert base. See illustration beside.
Once the custom hood base and frame are done, finalize the custom
hood.
P8
INTERIOR BLOWER
WITH
45
LB
56
LB
WARNING
!
I
INTERIOR BLOWER
WITH
N
53
LB
64
LB
HH0037A
9
" up
1 6
1 1/2"
HH0040A
- 6 -
-
E
.
(
LINE OR
XT
BLOWERS
ROUGH
31
LB
42
LB
Backsplash
(Optional)
-
)
IN PLATE ONLY
Plywood base
thickness: 3/4"
4" for liner
installation
24" to 30" above
cooking surface
Standard 36" h.
cooktop

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Best pik45

Tabla de contenido