Installation
Pos: 17 /Standard-Layout/Überschriften/1.1/1-spaltig/D - F/Ex-relevante technische Daten @ 25\mod_1232102144312_3101.doc @ 239424 @ 2 @ 1
4.2

Ex relevant specifications

Pos: 18 /Standard-Layout/Hinweise/Wichtig/Wichtig - Hinweis auf SM EX-Sicherheitshinweise FM/CSA (OI/CI) @ 31\mod_1245414843234_3101.doc @ 280321 @ @ 1
Important
An additional document with Ex safety instructions is available for measuring systems that are
used in explosion hazardous areas (Applies to FM / CSA only).
As a result, it is crucial that the specifications and data it lists are also observed.
Pos: 19.1 /Standard-Layout/Ex-relevante Technische Daten/Durchfluss/FCM2000/Sicherheitstechnische Daten ATEX / IECEx - Übersicht @ 31\mod_1246866904890_3101.doc @ 284283 @ @ 1

Overview of the different output options

ATEX/IECEx Zone 2
I
-
Output option A/B
-
in the order number
-
-
II
Output option D
in the order number
III
-
Output option X
and communication
option 3, 5, or 7
in the order number
Pos: 19.2 /Standard-Layout/Ex-relevante Technische Daten/Durchfluss/FCM2000/Version I: Stromausgänge aktiv / passiv @ 49\mod_1311943261715_3101.doc @ 416808 @ @ 1

Version I: Active/Passive current outputs

Types: ME21/ME22/ME23/ME24/ME25 and MC23
Current output 1
Active
Terminals 31/32
Current output 2
Passive
Terminals 33/34
Pulse output
Active or passive
Terminals 51/52
Contact output
Passive
Terminals 41/42
Contact input
Passive
Terminals 81/82
All inputs and outputs are electrically isolated from each other and from the supply power.
16 - EN
Current output 1: active
Current output 2: passive
Pulse output: active/passive,
switchable
Contact input and output: passive
Fieldbus communication
(PROFIBUS PA/FOUNDATION Fieldbus)
Protection type "nA" (Zone 2)
U
(V)
30
30
30
30
30
CoriolisMaster FCM2000
ATEX/IECEx Zone 1
-
Current output 1: active
-
Current output 2: passive
-
Pulse output: active/passive,
switchable
-
Contact input and output: passive
-
Current output 1: passive
-
Current output 2: passive
-
Pulse output: active/passive,
switchable
-
Contact input and output: passive
-
Fieldbus communication
(PROFIBUS PA/FOUNDATION Fieldbus)
I
U
(mA)
(V)
30
30
30
30
65
30
65
30
10
30
General operating values
I
b
b
(mA)
30
30
65
65
10
CI/FCM2000-EN