Installing The Material End Sensor - JUKI MO-6 14/LB-6 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 203

6. Installing the material end sensor

WARNING :
To protect against personal injury due to abrupt start of the machine, conduct maintenance works with
the power turned off.
(1) Installing the components
4
5
3
2
W4
1
Change the jumper pin for material end sensor from
+5V to +12V.
(+5V has been set at the time of delivery from the factory.)
The material end sensor does not oper-
ate properly unless this setting is per-
formed.
1) Install luminescence sensor 1 with screws 2 so
that it is in parallel to the cloth plate.
2) Fix the sensor cord 3 with cord clamp 5 so that it
is not caught with presser lifting lever 4.
35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mo-6 14r/lb-6 serie

Tabla de contenido