88
AVENTICS | Bus Coupler AES/Valve Driver AV, EtherNet/IP | R412018139–BAL–001–AF
PLC Configuration of the Valve System
Table 14:
Diagnostic data appended to input data
Byte no.
Bit no.
Meaning
Byte 6
Bit 0
Group diagnosis, module 33
Bit 1
Group diagnosis, module 34
Bit 2
Group diagnosis, module 35
Bit 3
Group diagnosis, module 36
Bit 4
Group diagnosis, module 37
Bit 5
Group diagnosis, module 38
Bit 6
Group diagnosis, module 39
Bit 7
Group diagnosis, module 40
Byte 7
Bit 0
Group diagnosis, module 41
Bit 1
Group diagnosis, module 42
Bit 2
Reserved
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
The group diagnostic data of the modules can also be accessed acyclically.
Diagnostic type and device
Group diagnoses of modules
Group diagnoses of modules