decimal points, and by the letter A for parameters
below 10, which are different from the first 10
parameters of simplified mode .
• MODALITA' STANDBY: makes the LED "POWER"
flash which indicates the presence of the power
supply voltage (decimal point of the furthest left
digit). It automatically switches to standby after
30 minutes of inactivity of the buttons around the
display
• TEST MODE the two digits on the left display
the name of the active command (for 5 seconds,
then it goes off), the two figures on the right
display, flashing, display the number of the safety
protection terminal block possibly in a state of
00
alarm (
if no safety protection is in a state
of alarm, then the control unit is enabled to run
commands; the only exception is when a limit
switch is activated, which is displayed, but is not
an obstacle to issuing a command).
protection in a state of alarm will be displayed until
it returns to rest; if there are two safety protections
in a state of alarm, the second one which is still in a
state of alarm appears after the first one has been
resolved, before displaying the safety protections
with the highest priority and then the other ones.
5.1
Commands and safety protections
status mode
The inputs are shown on the display in the following
way:
STATUS OF CONTROLS
AP
PED
PP
CH
ORO
POWER
FT = Photocells
ALWAYS ON
COS = safety edge
SB = Unlock
If the input is closed the corresponding segment
comes on. The segments corresponding to the
controls will normally be turned off (normally
open contacts), will be turned on upon receipt of
a command. The segments corresponding to the
safety protections installed must be turned on
(normally closed contacts); if they are turned off it
means that they are in a state of alarm.
SAFETY
PROTECTIONS
corresponding LED segment flashes
26
The safety
STATUS SAFETY PROTECTIONS
FT1
FT2
COS1
COS2
STOP
SB
DEACTIVATED:
the
5.2

Parameters mode

PARAMETER
UP
DOWN
PROG
UP
next parameter
DOWN
previous parameter
+
increases the parameter value by 1
-
decreases the parameter value by 1
PROG
programming the stroke (see par. 6)
TEST
enables test mode (see par. 5.4)
5.2.1

Changing a parameter

Using the UP and DOWN buttons to view the parameter
to be changed, then with the + and - buttons change its
value (the number on the right starts flashing).
While holding down a button, after one second
quick sliding is activated, allowing you to change
the parameter quicker. To save the value set on the
display, wait a few seconds, or move to another
parameter with the UP and DOWN buttons: the
whole display will flash quickly indicating that the
parameter has been saved.
NOTE: Changing the numerical value of the
parameters with the + and - buttons is only possible
with the engine stopped, while consultation of the
parameters is always possible.
The sequence of parameters in the mode simplified
is shown in the table in next page.
ATTENTION!
0-
The parameter
is particularly critic, and change this
with the system already started,may cause malfunction;
to give effect to the change in this value you have to
disconnect the power supply and then restart the
system and re-programming the stroke
5.2.2
Restoring standard factory
parameters
N.B.: this procedure is only possible if you have not
entered the password to protect your data.
Turn off the control unit, simultaneously press and
hold the UP and DOWN buttons then turn on again
and keep up pressing the buttons: after 4 seconds
the display will show the writing
VALUE
+
-
TEST
rE S-