Controls And Safety Device Status Mode; Parameters Mode; Modification Of A Parameter - Roger Technology AG/CTRL AGILIK Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
indicate the name of the parameter; the two digits
on the right indicate its numerical value. Please
see paragraph 5.2 for complete description.
• STANDBY MODE: the LED "POWER" blinks
indicating the presence of power (decimal point
of the left-most digit). Please see paragraph 5.3
for complete description.
• TEST MODE: the two digits on the left indicate the
name of the active command (for 5 seconds, then
it turns off); the two digits on the right display,
blinking, the number of the terminal of the safety
device in alarm (if any); the blinking code
displayed if the control unit is ready to perform a
command. In order to exit this mode, press once
again the TEST button. Please see paragraph 5.4
for complete description.
5.1

Controls and safety device status mode

The inputs are indicated on the display as follows:
STATUS OF THE COMMANDS
AP
PED
PP
CH
ORO
POWER
ALWAYS ON
FT = photocell
COS = safety edge
If the input is closed, the corresponding segment is
on. The segments corresponding to the commands
are usually off (the contacts are usually opened);
they will turn on when a command will be received.
The segments corresponding to the installed safety
devices must be on (the contacts are usually closed);
if they are turned off, they are in alarm status.
SAFETY DEVICES DISABLED FROM PARAMETER: the
corresponding LED segment blinks.
5.2

Parameters mode

PARAMETER
UP
DOWN
PROG
UP
next parameter
DOWN previous parameter
26
00
STATUS OF THE SAFETY DEVICES
FT
COS
STOP
RELEASE
inspection door
VALUE
+
TEST
+
increases by 1 the value of the parameter
-
decreases by 1 the value of the parameter
PROG
stroke programming (see paragraph 6)
TEST
it activates the test mode (see paragraph
5.4)
5.2.1

Modification of a parameter

Use the keys UP and DOWN to view the parameter
to be changed, then using keys + and – change its
value (the number on the right starts blinking).
is
By keeping the key pressed, after a second the quick
scroll will be activated, allowing you to change the
settings more quickly. In order to save the value set
on the display, wait 4 seconds or move to another
parameter using the keys UP and DOWN: the entire
display flashes quickly indicating that the setting
was saved.
NOTE: the modification of the parameters
numerical value using the keys + and - is possible
only if the motor is stopped; the parameters can be
viewed at any time.
The parameters sequence in the simplified mode is
indicated in the table of the next page.
IMPORTANT NOTE: the selection of the parameter
0-
A1
(
in extended mode) must comply with the
body of the machine, keeping in mind that the 6
meters barrier uses a different gear reducer from
the one corresponding to the 3m and 4m versions.
WARNING! The selection of this parameter is very
important for proper functioning of the automation
and for avoiding mechanical damages to the gear
reducer; this is why the factory set parameter is
that corresponding to the 6m barrier that has lower
speed and acceleration.
In relation to the selection of the parameter
A1
(
in extended mode) not all the indicated values
of the parameters
d-
(respectively
in extended mode) will be available: this happens
for safety reasons and is the responsibility of the
installer to set them correctly.
WARNING! The parameters
-
71
in extended mode) are particularly critical and
their modification, if the system is already on, may
cause malfunctions; in order to avoid them, the
power supply must be cut off while changing their
values; after this, the system must be restarted and
the stroke must be set once again.
8-
9-
A-
b-
,
,
,
33
40
11
34
,
,
,
,
0-
and
0-
C-
,
and
41
12
and
-
A1
(
and

Publicidad

Tabla de contenido
loading

Tabla de contenido