Changing A Parameter - Roger Technology B70/2DC Instrucciones Y Advertencias Para El Instalador

Centrale di comando 2 motori
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
3.5.2.1

Changing a parameter

Using the UP and DOWN buttons to view the parameter
to be changed, then with the + and - buttons change its
value (the number on the right starts flashing).
While holding down a button, after one second
quick sliding is activated, allowing you to change
the parameter quicker. To save the value set on the
display, wait a few seconds, or move to another
STANDARD
PARAMETER
AND VALUE
0- 02
Number of leaf
1- 00
Automatic reclosing
2- 30
Pause time
3- 00
Emergency blackout
4- 05
Phase shift closing M1
5- 00
Pre-flashing
6- 00
Step-by-step mode
7- 00
Flashing activation
8- 00
Enabling limit switch
Impact of force level
9- 15
motor 1
Livello forza d'impatto
A- 15
motore 2
b- 00
Pressure surge
C- 02
Motor model
24
VALUE
FUNCTION
DISPLAY
01 - 15 number of attempts to reclose (interrupted by
00 - 90 seconds of pause
92 - 99 2 minutes...9 minutes of pause
01 - 30 phase shift seconds
01 - 10 pre-flashing seconds
01 - 10 low torque motor
11 - 19 medium torque motor
01 - 10 low torque motor
11 - 19 medium torque motor
parameter with the UP and DOWN buttons: the
whole display will flash quickly indicating that the
parameter has been saved.
NOTE: Changing the numerical value of the
parameters with the + and - buttons is only possible
with the engine stopped, while consultation of the
parameters is always possible.
The sequence of parameters in the mode simplified
is shown in the table below.
ON
1 leaf
01
2 leaf
02
deactivated
00
photocell) before finally staying opened
always tries to reclose
99
deactivates the reclosing when power returns
00
enables the reclosing when power returns
01
deactivated
00
deactivated
00
5 seconds of pre-flashing only when closing
99
opens stops closes stops opens stops closes ..
00
condominium, refreshes the pause time
01
condominium, closes from completely open
02
opens closes opens closes
03
opens closes stops opens
04
fixed
00
one flash per second
01
normal flash when opening, fast when closing
02
no limit switch connected
00
limit switch on opening connected
01
1 minimum impact force ... 10 max. impact force
11 minimum impact force ... 19 max. impact force
Maximun torque motor
20
Without anti-crushing protection (obligatory safety edges)
1 minimum impact force ... 10 max. impact force
11 minimum impact force ... 19 max. impact force
Maximun torque motor
20
Without anti-crushing protection (obligatory safety edges)
deactivated
00
enabled
01
piston BM20 BRUSHLESS
01
piston BR20 BRUSHLESS
02
articulated arm BR23 BRUSHLESS
03
underground motor BR21 BRUSHLESS
04
DESCRIPTION

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido