Cebora KINGSTAR 400 TS Manual De Instrucciones página 109

Ocultar thumbs Ver también para KINGSTAR 400 TS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Code
Type
90
[W]
CNC not ready. In robotised
applications with connection to
interface Items 448, 428.XX or
direct connection to CNC.
91
[W]
Wire stuck error "STI"
92
[W]
End of wire error "END"
95
[W]
Bluetooth mask not connected
97
[W]
Voltage measurement cable not
connected
98
[W]
Arc does not strike within the
timeout
99
[E]
Machine is powering down.
3301065/A
Error Description
Check connection to power source CN2, check the robot ready
signal is present on the interface or CNC. Check the accuracy
of robot interface parameters, check the interface and power
source terminal DIP switches. Turn off and on. If the problem
persists, contact technical assistance.
Active only in robot mode. Check that the welding wire is not
attached to the workpiece. If the error persists, contact techni-
cal assistance.
Active only in robot mode. Check for wire in the spool. If the
error persists, contact technical assistance.
Check the mask battery. Connect the mask to the power
source in accordance with the procedure described in the ma-
nual. If the problem persists, contact technical assistance.
Check that the cable supplied is properly connected to SRS kit
Item No 443 or to UPGRADE 3D-Pulse Item No 814. If the error
persists, contact technical assistance.
Section 7.3.4 of the manual, check that the parameter is pro-
perly set. If the problem persists, contact technical assistance.
Wait for the power source to power down. During this stage, do
not turn the power source back on by turning the mains switch
because the power source would lock. Turn off the machine,
wait for at least 30 seconds and turn back on.
Action
109/109

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kingstar 520 tsKingstar 400 ts robotKingstar 520 ts robot372 00374 00372 80 ... Mostrar todo