Cebora KINGSTAR 400 TS Manual De Instrucciones página 78

Ocultar thumbs Ver también para KINGSTAR 400 TS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Set the following values using the "PARAMETERS" pushbutton on the main menu:
Preflow. Adjustment ranges from 0.1 to 10 seconds Turn knob I to
change the value, press to confirm.
Postflow. Adjustment ranges from 0.1 to 25 seconds Turn knob I to
change the value, press to confirm.
Gas Flow. Active only with Kit 436. Adjustment ranges from 5 to 30 l/
min. Turn knob I to change the value, press to confirm.
Wire Weight. Welding wire consumption is shown in grams per metre
to calculate spool consumption. The value must be preset. Use the
default value if the weight of the wire is not known.
Soft Start. The adjustment can vary from 10 to 100%. This is the wire
feed speed expressed as a percentage of the speed set for welding,
before the wire touches the workpiece to be welded. This adjustment
is important for achieving effective start-ups. Press AUTO to call up
the factory settings.
Burnback. The adjustment can vary from -125 to +125 ms. Its purpose
is to adjust the length of wire emerging from the gas nozzle after
welding. A positive figure means more wire has been burnt and the
amount sticking out is shorter. Press 0 to call up the factory settings.
78/109
3301065/A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kingstar 520 tsKingstar 400 ts robotKingstar 520 ts robot372 00374 00372 80 ... Mostrar todo

Tabla de contenido