Mig Welding; Power Source-Wire Feeder Connection; Selecting The Synergistic Curve - Cebora KINGSTAR 400 TS Manual De Instrucciones

Ocultar thumbs Ver también para KINGSTAR 400 TS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4

MIG WELDING

4�1

Power source-wire feeder connection

Connect the earth cable to the socket L(-)�
Connect the power cable of the power source-wire feeder connection to rear socket N (+)�
Connect connector of power source-wire feeder service connection to rear connector M�
Connect the connectors for managing SRS Item No 443 (option) of the power source-wire feeder connection to rear
connectors O-Q.
Connect wire feeder Item No 5690133 (manual) or Item No 1648 (Robot, see instruction Item No 3301052) to the power
source via the power source-wire feeder connection Item No 2061
4�2

Selecting the synergistic curve:

Select the DC pushbutton or access the submenu using pushbutton DI (see Fig 10)
3301065/A
Select the Material
Select the wire type
Select wire diameter
Select the gas type
Select the welding process
Use pushbutton I (Fig. 7) to select the welding process from
among those available based on the previous selections,
confi rmed by pressing the knob I.
73/109

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kingstar 520 tsKingstar 400 ts robotKingstar 520 ts robot372 00374 00372 80 ... Mostrar todo

Tabla de contenido