2.3.11 Replacing the headband padding

The foam padding can be removed from the adhesive strap and replaced with new foam padding.

2.3.12 Care instructions

General note
The cleaning and disinfecting of medical devices serves to protect the patient, user, and third parties, and also to maintain the overall value of the medical devices.
Due to the product design and materials used, a defined limit for the maximum possible number of reprocessing cycles cannot be determined. The service life of
medical devices is defined by their designed and intended function and appropriate, careful handling.
Before returning for repair, defective products must have undergone the prescribed cleaning and disinfection process.
Cleaning and Disinfection
In order to avoid possible cross-contamination, the examination lamps must be cleaned and disinfected regularly.
The examination lamps can be cleaned on the outside using a damp cloth (if necessary, moistened with alcohol) until they are visually clean. Wipe with disinfectant
(e.g. disinfectant Bacillol AF from Bode Chemie GmbH (time 30s)) according to the instructions of use by the respective manufacturer of the disinfectant. Only disinfec-
tants with proven effectiveness according to national guidelines should be used. After disinfecting, wipe the examination lamps with a damp cloth to remove potential
residue.
Please make sure that the cloth is moistened but not wet, so no moisture penetrates the openings of the examination lamp.
Make sure that glass and lenses are only cleaned with a dry and clean cloth.
Caution!
The examination lamps are not sterile devices; they cannot be sterilized.
Caution!
The power supply adapter must be unplugged from the outlet before cleaning or disinfecting the device!
Never place the examination lamps in liquids!
Make sure no liquids penetrate the housing interior!
The device is not approved for machine reprocessing and sterilization.
This can lead to irreparable damage!
If a reusable device shows signs of material deterioration, it should no longer be reused and should be disposed of/claimed according to the procedure described in
the Disposal/Warranty sections.

3. Spare parts

Art. no. 11302
6 V bulbs for clar N LED
Art no.11284
230 V plug-in charger
Art. no. 11286
120 V plug-in charger
Art. no. 11287
Set of CR 123A lithium batteries
Art. no. 11288
Set of NiMH AAA batteries
Art. no. 11289
Foam strip, 120 mm long
Art. no. 11293
Fleece dots, Ø 35 mm
Art. no. 11294
Fleece dots, Ø 47 mm
Art. no. 12680
Battery compartment cover for lithium CR 123A
Art. no. 12681
Battery compartment cover for NiMH AAA batteries
Art. no.11301
6 V vacuum lamps, 6 units
Art. no. 11302
LED lamp, 1 unit
Art. no.11287
Lithium CR 123A, 2 units
Art. no. 11288
NiMH AAA batteries, 4 units
Art. no. 11284
230 V plug-in charger
Art. No. 11286
120 V plug-in charger