Consulting The Luminaires Failures Stored In Memory - Zemper PZD-250 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Consulting the luminaires failures saved in memory.
To consult the failures of the luminaires saved in the different "ZONES", follow these steps:
From the "MAIN MENU", with the scroll buttons, select "STATUS"
Press "OK" to confirm the selected option.
The following screen appears ("SCREEN 1"):
SELECTION
With the scroll buttons, select the memory address ("ZONE") where you want to consult the information
saved.
Press "OK" to confirm the selected option.
The following screen appears ("SCREEN 2"):
SELECTION
With the scroll buttons, select "ERRORS"
Press "OK" to confirm the selected option.
The following screen appears ("SCREEN 3"):
The following information appears on the screen:
Press "ANUL." to get out of this screen and return to the SCREEN 2.
Press "ANUL." to get out of the SCREEN 2 and return to the SCREEN 1.
Press "ANUL." to get out of the SCREEN 1 and return to the main screen "MAIN MENU".
The failures that can appear on the SCREEN 3 are the following ones:
EMERGENCY L.: the luminaire has a failure of emergency lamp. In the case there is more than one
emergency lamp, it indicates that at least one of them has a failure. This failure can be due to a bad
connection of the lamp, lamp failure. To correct this failure, replace the lamp correctly or change it for a new
one (depending on the case).
BATTERY: The battery of the luminaire is disconnected, damaged or the protection fuse of the battery is burnt.
To correct this failure, check the connections of the battery, the protection fuse of the battery or change the
battery for a new one if it would be necessary.
STATUS MENU
Set Zone:
ZONE 1
ZONE 2
ZONE 3
ZONE 4
STATUS MENU
ZONE X STATUS
LUMINARIES
ERRORS
DELETE ZONE
ZONE 2
1
LUM.
2
125
3
1/ Memory "ZONE" selected.
2/ Number of luminaire with a type of failure and saved in the selected memory.
3/ List of failures. The failures of each luminaire that have a type of failure are shown.
4/ Indicates that the information relative to the failures has more lines than the shown on the screen.
To see the hidden lines (up or down of the screen), you will use the scroll buttons.
ZONE 5
ZONE 6
ZONE 7
ZONE 8
ERRORS
DURATION
35
SCREEN 1
SCREEN 2
4
SCREEN 3